Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol Heart Vasc ; 42: 101109, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36110246

RESUMO

Background: A novel catheter technology (direct sense, DS) enables periprocedural local impedance (LI) measurement for estimation of tissue contact during radiofrequency ablation (RFA) for real-time assessment of lesion generation. This measure reflects specific local myocardial conduction properties in contrast to the established global impedance (GI) using a neutral body electrode. Our study aimed to assess representative LI values for the cardiac chambers, to evaluate LI drop in response to RF delivery and to compare those values to established GI measures in patients undergoing RFA procedures. Methods and Results: Seventy-three patients undergoing RFA with the DS technology were included. Within the cardiac chambers, baseline LI was significantly different, with the highest values in the left atrium (LA 107.5 ± 14.3 Ω; RV 104.6 Ω ± 12.9 Ω; LV 100.7 Ω ± 11.7 Ω, and RA 100.5 Ω ± 13.4 Ω). Baseline LI was positively correlated to the corresponding LI drop during RF delivery (R2 = 0.26, p = 0.01) representing a promising surrogate of lesion generation. The observed mean LI drop (15.6 ± 9.5 Ω) was threefold higher as GI drop (4.9 ± 7.4 Ω), p < 0.01. We evaluated the clinical outcome in a subgroup of patients undergoing DS-guided pulmonary vein isolation, which was comparable regarding arrhythmia recurrence to a conventional ablation cohort (57 % vs 50 %, p = 0.2). Conclusion: We provide detailed information on LI measures in electrophysiological procedures with significant differences within the cardiac chambers highlighting that RFA-related LI drop can serve as a promising surrogate for real-time assessment of lesion generation. Guiding the electrophysiologist in RFA procedures, this additional information promises to improve safety profile and success rates in the interventional treatment of arrhythmias.

3.
Artigo em Inglês | MEDLINE | ID: mdl-33533993

RESUMO

Premature atrial complexes (PACs) are a common finding in patients with structural heart disease, as well as in healthy subjects. In addition to the clinical spectrum ranging from asymptomatic patients to irritating palpitations, PACs are suggested to be associated with an increased risk of atrial fibrillation and stroke. Medical treatment leads to a significant reduction in PACs with clear symptom relief in a large proportion of patients, but is limited in cases of PACs that are refractory to antiarrhythmic drug (AAD) treatment. Furthermore, proarrhythmic effects of AAD or the patient's refusal of AAD treatment due to side effects need to be considered. Ablation of PACs is a good alternative to medical therapy with a comparable safety profile and at least comparable efficacy. In recent years, ultra-high-density (UHD) mapping with multiple improvements for successful ablation has been evolving. Before the introduction of UHD mapping, ablation strategies included activation mapping with single-tip catheters or conventional mapping aiming for the earliest activation of the PAC locally, with the earliest activation suspected to be the origin of the PAC and targeted by radiofrequency (RF) ablation. Using UHD mapping, a three-dimensional local activation map of the atrium can be acquired, identifying the point of earliest activation within the high-resolution map. PAC ablation has therefore developed into a true alternative for the treatment of symptomatic PACs.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/cirurgia , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
4.
Sci Rep ; 9(1): 8830, 2019 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-31222008

RESUMO

Pulmonary vein isolation (PVI) as interventional treatment for atrial fibrillation (AF) aims to eliminate arrhythmogenic triggers from the PVs. Improved signal detection facilitating a more robust electrical isolation might be associated with a better outcome. This retrospective cohort study compared PVI procedures using a novel high-density mapping system (HDM) with improved signal detection vs. age- and sex-matched PVIs using a conventional 3D mapping system (COM). Endpoints comprised freedom from AF and procedural parameters. In total, 108 patients (mean age 63.9 ± 11.2 years, 56.5% male, 50.9% paroxysmal AF) were included (n = 54 patients/group). Our analysis revealed that HDM was not superior regarding freedom from AF (mean follow-up of 494.7 ± 26.2 days), with one- and two-year AF recurrence rates of 38.9%/46.5% (HDM) and 38.9%/42.2% (COM), respectively. HDM was associated with reduction in fluoroscopy times (18.8 ± 10.6 vs. 29.8 ± 13.4 min; p < 0.01) and total radiation dose (866.0 ± 1003.3 vs. 1731.2 ± 1978.4 cGy; p < 0.01) compared to the COM group. HDM was equivalent but not superior to COM with respect to clinical outcome after PVI and resulted in reduced fluoroscopy time and radiation exposure. These results suggest that HDM-guided PVI is effective and safe for AF ablation. Potential benefits in comparison to conventional mapping systems, e.g. arrhythmia recurrence rates, have to be addressed in randomized trials.


Assuntos
Fibrilação Atrial/terapia , Veias Pulmonares/cirurgia , Idoso , Ablação por Cateter , Mapeamento Epicárdico/métodos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Exposição à Radiação , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...